Port Specifications

USB Downstream Port Properties
Short Circuit Detection Time (ms) Max -   Vbus Output Current, ALT CDP Mode (A) Max 2.4
Short Circuit Response Time (ųs) Max -   Vbus Output Current, CDP Mode (A) Max -
USB D Logic Low Voltage (V) Min 0   Vbus Output Current, DCP Mode (A) Max -
Max 0.3   Vbus Output Current, SDP Mode (A) Max -
USB D Logic High Voltage (V) Min 2.8   Vbus Output Power (W) Max -
Max 3.6   Vbus Output Voltage (V) Min 4.8
USB Hi-Speed Data Rate (Mbps) Nom -   Nom 5
USB SuperSpeed Data Rate (Gbps) Nom -   Max 5.2
Vbus Current Measurement Accuracy (%FSR) Min -   Vbus Source Power (W) Max -
Max -   Vbus Voltage Measurement Accuracy (%FSR) Min -
Vbus Current Measurement Range (A) Min -   Max -
Max -   Vbus Voltage Measurement Range (V) Min -
Vbus Current Measurement Rate (Hz) Nom -   Max -
Vbus Current Measurement Resolution (mA) Nom -   Vbus Voltage Measurement Rate (Hz) Nom -
Vbus Current Setpoint Resolution (mA) Nom -   Vbus Voltage Measurement Resolution (mV) Nom -
Vbus Output Current (A) No 2.4   Vbus Voltage Ripple (mV) Max -
        Vbus Voltage Setpoint Resolution (mV) Nom -

Table 5-13

 

Table 5-14

Ports Lifetime

Standard USB connections have a minimum rated lifetime of 1,500 cycles of insertion and removal. USB-C receptacles have a minimum rated lifetime of 10,000 cycles of insertion and removal. This is an industry-standard.

One thing you can do to prolong the lifetime of the ports on your MultiCharger14-2.4A is to use "sacrificial cables" in between the hub and your charging cables so when you repeatedly connect/ disconnect you are only going to wear the cables rather than the hub.